Fire fighting panels

Fire pump control panels

Controllers for main, jockey and diesel fire pumps, built so the system starts reliably when pressure drops and shows its status clearly.

Panels in this range

  • Main pump control
  • Jockey pump control
  • Diesel pump control
  • Alarm and safety interlocks

What we build

Fire fighting panels we make

Main pump control

Starts the electric main fire pump automatically on a pressure drop, with manual start, clear status indication and the stop logic your fire code and consultant specify.

Jockey pump control

Keeps the fire main pressurised by starting and stopping the jockey pump on pressure, so small leaks don’t start the main pump.

Diesel pump control

Starts the diesel engine pump on pressure drop or main pump failure, with battery charging, engine start attempts and fault indication.

Alarm and safety interlocks

Audio-visual alarms, pump run and fault indication, and potential-free contacts for the fire alarm system or BMS.

Inside the panel

Built to start when it matters

A fire pump panel can sit idle for months and then has to work first time. Clear indication and easy testing are part of the design.

  • Pressure switches or transmitters for automatic starting
  • Phase failure and supply indication on the panel door
  • Run, fault and trip indication for every pump
  • Test facilities for routine pump trials
  • Built to your consultant’s specification and local fire authority requirements
  • Status contacts for fire alarm panels and BMS

Pumps we control

  • Electric main fire pump
  • Jockey pump
  • Diesel engine fire pump
  • Sprinkler and hydrant pumping systems

Where they’re used

Industries we build these for

Commercial buildingsResidential towersManufacturing plantsWarehousesFire protection contractors

Make it a smart panel

Add remote monitoring, cloud data logging and SMS or app alerts to any panel in this range.

See smart panels

Questions and answers

Questions about fire fighting panels

What does a jockey pump do?

The jockey pump keeps the fire main pressurised and makes up small losses, so the main fire pump only starts when there is a real demand, such as an open hydrant or sprinkler.

When does the diesel fire pump start?

The diesel pump starts automatically when pressure keeps falling or the electric main pump fails to start, so the system still has water if power is lost.

Do you build fire pump panels to consultant specifications?

Yes. Panels are built to your consultant’s specification and local fire authority requirements, including the start and stop logic, alarms and indication.

Can the panel send status to the fire alarm system or BMS?

Yes. Potential-free contacts give pump run, fault and trip status to the fire alarm panel or BMS.

Get a quote

Get a price for fire fighting panels

Send what you have, even if it is only a few lines. We reply with questions, a drawing and a price.

For a quick quote, send

  • Main, jockey and diesel pump ratings
  • Starter type for the main pump
  • Pressure settings or system design pressure
  • Consultant specification, if any
  • Site location and timeline